The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T21CM05348
Parcel: 12009247C

Address:
4530 S 2ND AV 1

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM05348
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/14/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change COMPLY WITH ZOING COMMENTS FOR APPROVAL OF A STRUCTURE INSIDE THE PROPERTY SETBACK.

A complete plan set showing 2018 IRC compliance is required for a permit.

If the DDO is approved the structure must also comply with the 2018 IRC building code. 1. The roof may not be closer than 2 feet to the property line. 2. The part of roof within 3 feet to the property line requires one-hour fire rated material on the roof underside.

Fire rated constructiion may be avoided when all parts of the structure is 3 or more feet from the property line. A porch roof may be placed inside of the 3 foot fire separation distance to property line if a one-hour rated wall is extended from ground to roof and from end to end.
10/20/2021 STEVE SHIELDS ZONING REVIEW Approved