Permit Number: T21CM05348
Parcel: 12009247C

Address:
4530 S 2ND AV 1

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM05348
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/09/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM05348
4530 S 2nd Ave
Porch Addition (2nd Review)

TRANSMITTAL DATE: August 4, 2021

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10

The following comments were not addressed.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This plot plan will include but not limited to:
a. Shall include the entire parcel
b. All structures on site
c. The lot coverage shall include the percent of lot coverage
d. Provide the legal description on the plot plan
f. Provide the zoning of the parcel and adjacent parcels on the plot plan
g. Show the utilities on the plot plan

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A.

2. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height less than 9’-0” the required perimeter yard from the proposed porch to the west property line is 6’-0”, proposed setback based on the location of the post supporting the porch is 2’-2”.


If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.
08/11/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change COMPLY WITH ZOING COMMENTS FOR APPROVAL OF A STRUCTURE INSIDE THE PROPERTY SETBACK.

If the DDO is approved the structure also required to comply with building code safety. 1. The roof may not be closer than 2 feet to the property line. 2. The part of roof within 3 feet to the property line requires one-hour fire rated material on the roof underside.

Fire rated constructiion may be avoided when all parts of the structure is 3 or more feet from the property line.