Permit Number: T21CM05324
Parcel: 108203100

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM05324
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2021 SBLOOD1 ENGINEERING REVIEW Completed
07/14/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM05324
4142 N Fortune Lp
New SFR attached (1st Review)

TRANSMITTAL DATE: July 14, 2021

This site is located in the R-2 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. As the Average Daily Traffic exceeds 140 this proposed dwelling does not qualify to use UDC Article 6.4.5.C.2.b.(2) therefor the required perimeter yard setback from the garage to the street property line is 18’, 19’ to back of sidewalk.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
07/22/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.

Provide the total developed length from meter to the most remote appliance on the system, and verify the size of the supply pipe for the connected demand (may require upgrading), G2413.3 & Table G2413.4(1).