Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM05278
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2021 | AWARNER1 | NPPO | REVIEW | Passed | |
| 07/15/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM05278 1122 S Eli Dr Storage Container Addition (1st Review) TRANSMITTAL DATE: July 15, 2021 This site is located in the R-1 zone (UDC 4.7.7). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. At a minimum this plot plan will: a. Show the correct legal description “YALE ESTATES LOT 17 BLK 14” b. Be drawn to an engineering scale c. Have a complete lot coverage calculation d. Show the zoning of the parcel and all adjacent parcels e. Reflect the parcel size and shape shown on the plat and provide the parcel dimensions f. Show the utilities on the plot plan. 2. As the storage container does not meet perimeter yard setbacks an you are attempting to use the neighbor setback waiver the setback waiver needs to be on the plot plan that clearly shows the storage container and the proposed setbacks. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
| 07/21/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Passed | |
| 07/29/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: 1. Is this for a new or existing activity application? - Please select New Application. 2. Submission Type - Select Floodplain Use Permit. 3. Project Name - Enter a name for your project. 4. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. 5. Type of Permit - Select Commercial or Residential (Residential is for work on single family residences and duplexes.) 6. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account. 7. Complete the Contractor, Owner and Architect/Engineer sections as applicable. 8. Supporting Documentation Upload - Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful. 9. Sign the application and submit. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |