Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM05201
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/07/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 03/15/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM05201 6021 E 30th St – R-1 New SFR (2nd Review) TRANSMITTAL: March 15, 2022 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. Provide a detailed response letter, which states how all Zoning Review Section comments were addressed. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A. The following comments were not addressed: Based on the 12” dimension from finished floor shown on the plan depending on the provided dimensions 6” or 12” has been added to the wall height dimensions. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. Based on a wall height of 18’-1”, for the peaked roofed area, the required perimeter yard setback from the proposed SFR to the east property line is 12’-1”, proposed setback is 6’-0”. 2. Based on a wall height of 14’-0”, for the northern parapet wall area, the required perimeter yard setback from the proposed SFR to the east property line is 9’-4”, proposed setback is 6’-0”. 3. Based on a wall height of 9’-7”, for the southern pitched roof area, the required perimeter yard setback from the proposed SFR to the east property line is 6’-5”, proposed setback is 6’-0”. 4. Based on a height of 9’-8”, from grade to bottom of rafter for the proposed porch , the required perimeter yard setback to the west property line is 6’-6”, proposed setback is 6’-0” 5. Based on a wall height of 18’-1”, for the peaked roofed area, the required perimeter yard setback from the proposed SFR to the west property line is 12’-1”, proposed setback appears to be about 10’-2”. No setback dimensions provided to this area. 6. Provide perimeter yard setback dimensions from the west property line to the posts supporting the porch roof and all vertical walls so that setback requirements can be verified. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 03/22/2022 | JPEELDA1 | FIRE | REVIEW | Approved |