Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM05166
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/23/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 06/28/2021 | AWARNER1 | NPPO | REVIEW | Passed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: 1033 N Natachee, garage addition Activity No.: Tcm21-05166 TRANSMITTAL DATE: June 28, 2021 DUE DATE: July 9, 2021 7.7. Native Plant Preservation An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) is NOT required, but recommended, prior to Grading Plan approval. By far, the best way to satisfy this requirement is to preserve 30% of the lot as Natural Undisturbed Open Space. On this site, indicate graphically what area will remain in place and provide calculations that 30% of the site will remain undisturbed. If you have any questions about this transmittal, Contact me by email at anne.warner@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: NPPO Plan or NPPO Exception request |
| 07/13/2021 | LSHAMIS1 | ZONING | REVIEW | Reqs Change | CDRC Transmittal FROM: Loran Shamis PDSD Zoning Review Section PROJECT: T21CM05166 Prentice Residence 3 car garage (1st Review) 1033 N Natachee TRANSMITTAL DATE: July 13, 2021 DUE DATE: July 12, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The site is in the R-1 zone, single family residential is permitted use in this zone. See use specific standards 4.9.7.B.5 - .9. 01. COMMENT: Per UDC, 6.6.2.B, an accessory building shall be built only on a lot occupied by a principal building or use. The single-family residence is the principal use located on parcel 13320006A, and the proposed garage is an accessory building and is located on parcel 13320006B, a separate parcel from the single-family dwelling unit, and this is not permitted. If you have any questions about this transmittal, Contact Loran Shamis at Loran.Shamis@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 07/19/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM05166 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. A special inspection request is required with the permit application for welding, R109.2. STRUCTURAL PLANS: 1. Specify steel lintels to support imposed load, R606.10: 1’ to 4’ 2-3 ½”x3 ½” x ¼” 4’ to 7’ 2-4” x 3 ½” x 5/16” 7’ to 9’ 2-5” x 3 ½” x 5/16” 9’ to 10’ 2-5” x 3 ½” x 3/8” 10’ to 12’ 2- 6” x 4” x 3/8” 12’ to 15’ 2- 6” x 4” x 7/16” 15’ to 18’ 2- 8” x 4” x ½” ELECTRICAL PLANS: 1. Show service panels on a Riser Diagram for each building. Size the feeder, NEC 225.30 and E3403. 2. Provide a panel schedule, E3602.1 & E3706.2. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Adjustable security light fixtures are unshielded, not FCO. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |