Permit Number: T21CM05130
Parcel: 133152900

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM05130
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2021 CLAYTON TREVILLYAN ELECTRICAL-COMMERCIAL REVIEW Passed NO ELECTRICAL INCLUDED IN EXTERIOR PATIO AREA
06/24/2021 CLAYTON TREVILLYAN MECHANICAL-COMMERCIAL REVIEW Passed
06/24/2021 CLAYTON TREVILLYAN PLUMBING-COMMERCIAL REVIEW Passed
06/24/2021 CTREVIL1 WATER REVIEW Passed
06/30/2021 JVINCEN1 FIRE REVIEW Reqs Change 1) New patio gates x 2 shall swing in the direction of egress travel due to the OL > 49. IFC 1010.1.2.1. Gate shall not have locking hardware unless it is panic hardware. IFC 1010.1.10
2) Inspector to verify existing doors that lead to patio are equipped with panic hardware. Exception is main door.
IFC 1010.1.10 (exp 1).
07/14/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet G-1; Code Check: Please indicate separately the square footage and occupant load of each exterior patio space, verifying one exit for each patio is adequate.
2. Sheet A-1; Floor Plan: Please indicate on this plan the table arrangements, and indicate the number of required accessible seating spaces and the location of those spaces per the IBC Section 1109.11.
3. General: Please provide written responses to all review comments.
07/19/2021 SSHIELD1 ENGINEERING REVIEW Reqs Change See Zoning comments
07/19/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM05130
6958 E Tanque Verde Rd
Patio Addition & Patio Cover on Existing Patio

TRANSMITTAL: July 19, 2021
This site is located in the C-1 zone (UDC 4.7.20), Food Service is an allowed use in the zone (UDC Table 4.8-4) subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O.

1. As you are proposing a patio addition to a Commercial Site a Development Package (DP) is required. This DP shall at a minimum meet the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf. The DP is a separate submittal from the building plan and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using the “Submission Type”, “Site Review”. Zoning cannot approve the building plan until the DP has been approved. Until the DP is submitted and approved Zoning cannot approve this permit.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
07/19/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed