Permit Number: T21CM05117
Parcel: 12515035D

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM05117
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
08/09/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL
PDSD Zoning Review
T21CM05117
Residential Addition
August 9, 2021
The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.
2. Please add any accessory structures to the site plan. It appears that the shade structure in the back yard is unpermitted. Please add the gazebo to the permit on the next submission. If the structure is no longer there, please indicate that on the plans.
a. The shade structure does not appear to meet perimeter yard setbacks. It can be tied into the DDO, or the applicant can provide a neighbor waiver for the structure from the neighbors to the east, and both southern neigbors. If the applicant goes this route, please post the following language on the site plan, accompanied by the neighbor signatures:
“My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________”
If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
08/19/2021 JVINCEN1 FIRE REVIEW Reqs Change This residence will have a “fire-flow calculation area”(2018 IFC Appendix B, Section B102 and 105.1) greater than 3,600 sq. ft.: therefore this house will require a residential sprinkler system unless the fire flow in the nearest hydrant is a minimum of 1,750 GPM for 2 hours duration at 20 psi residual pressure. Additionally, the hydrant must be within 600’ of all parts of the residence. Contact Tucson Water engineering for a hydraulic analysis. Provide notes on plan regarding verification of fire flow, proximity of hydrant and include intent to install a fire sprinkler system. If a system will be installed, residential or quick response sprinklers shall be used. The sprinkler system may be connected to the domestic water supply, provided the required design density can be met. Be advised that Tucson Water will not allow a residential sprinkler system to be supplied by a 5/8" meter. A minimum of ¾” meter will be required by Tucson Water. Residential fire sprinkler system shall be installed in accordance with the 2018 IFC and NFPA 13D.