Permit Number: T21CM05117
Parcel: 12515035D

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM05117
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/23/2021 SBLOOD1 ENGINEERING REVIEW Passed
07/08/2021 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T21CM05117
Residential Addition
July 8, 2021
The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.
1. The required perimeter yard setback in the RX-2 zone for a residential use to a residential zone is 20'. The current setback for the carport on the EAST side of the residence appears to be around 17' from the property line. The applicant may choose to move the carport in to meet the perimeter yard setback. Alternatively, the applicant may also apply for a Design Development Option (DDO) to reduce the required 20' setback.
a. The information about the DDO can be found here: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. More information is required before zoning can write a referral to the DDO process. Please add the exact proposed setback from the carport to the property line.
2. Please add any accessory structures to the site plan. It appears that the shade structure in the back yard is unpermitted. Please add the gazebo to the permit on the next submission. If the structure is no longer there, please indicate that on the plans.
a. The shade structure does not appear to meet perimeter yard setbacks. It can be tied into the DDO, or the applicant can provide a neighbor waiver for the structure from the neighbors to the east, and both southern neigbors. If the applicant goes this route, please post the following language on the site plan, accompanied by the neighbor signatures:

“My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________”

3. The address submitted on the application appears to be incorrect. The applicant listed the property as 80 E Calle Primarosa. The address appears to be 84 E. Calle Primaros. Please submit a letter upon the next submittal asking to change the address.

If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
07/15/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM05117

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

SITE PLAN:

Provide a site plan showing all buildings, R106.1.1. Show the location of utility lines to the building.

FLOOR PLAN:

Provide a floor plan showing each room with labeled function and dimensions. Include the identification of adjacent rooms with door or window opening into the proposed space.

SECTIONS - DETAILS:

Provide the placement of ceiling/roof insulation. This determines the need for attic ventilation or the need for an air-impermeable layer if insulation at the roof sheathing.

PLUMBING PLANS:

Provide piping details showing code compliant materials and sizes.

MECHANICAL PLANS:

Provide equipment details showing code compliant components, locations and sizes. Provie a Manual J report identifying cooling demand.

ELECTRICAL PLANS:

Provide wiring details showing code compliant devices and sizes. Show circuit number and size with receptacles at all walls and lighting control at each doorway both interior and exterior. Receptacle, lighting and smoke detector circuits require arc-fault protection.

INTERNATIONAL ENERGY CONSERVATION CODE:

Provide insulation details minimum (R-13 walls and R-38 ceiling) showing code compliant placement of materials and ratings, N1101. Windows require a solar heat gain of 0.25 or better.

OUTDOOR LIGHTING CODE

Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations or show proposed fixtures as Full Cut Off (night sky friendly).

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review