Permit Number: T21CM05103
Parcel: 14028033A

Address:
6424 S TUCSON BL

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM05103
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2021 SBLOOD1 ENGINEERING REVIEW Passed
06/23/2021 JPEELDA1 FIRE REVIEW Approved
06/29/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. General: Please provide a site plan indicating the location of the building that will house the new paint booth.
2. General: Please provide a floor plan that dimensionally locates the new paint booth.
07/01/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. Provide construction documents drawn to scale and with sufficient detail and clarity to demonstrate that the work complies with the applicable codes. Reference: Section 107.2.1, IBC 20188.
2. Verify that the termination of exhaust fan is more than 30 feet from the property line. Reference: Section 501.3.1 (1), IMC 2018Show that the equipment is being installed in accordance with the conditions of its listing and the manufacturer’s installation requirements. Reference: Section 304.1, IMC 2018.
3. Provide air balancing data to show that adequate make-up air will be provided to the room in which the paint booth is located so that the room pressure remains essentially neutral. Reference: Section 501.4, IMC 2018.
07/01/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide a complete diagram of the natural gas distribution system showing the all of the loads, developed lengths, the layout of the distribution piping and the gas pressure at the meter. Reference: Section 402.2, IFGC 2018.
2. Delete duplicate drawings in the submittal.
07/01/2021 ROBERT SHERRY WATER REVIEW Completed
07/13/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the following electrical plan review comments. Also provide a written response.

Provide complete electrical plans designed and sealed by a Engineer registered in the State of Arizona.

Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2012 Tucson/Pima County Outdoor Lighting Code (OLC),

City of Tucson Commercial Plan Submittal Requirements
07/14/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM05103
6424 S Tucson Blv.
Paint Booth Addition

TRANSMITTAL: July 14, 2021
This site is located in the PI zone (UDC 4.7.28). General Manufacturing is an allowed use in the zone (Table 4.8-5) subject to Use Specific Standards 4.9.5.C.2, .4, .5, .6, & .8 and 4.9.13.Q

1. Clearly show where the paint booth will be located on site.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
07/16/2021 JGARCIA1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed