Permit Number: T21CM04905
Parcel: 11808105A

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM04905
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/23/2021 SBLOOD1 ENGINEERING REVIEW Passed
07/07/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM04905
1424 S Verdugo Ave
2 Story Addition (1st Review)

TRANSMITTAL DATE: July 7, 2021

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Based on current aerial photos there are numerous shade/accessory structures on site, some that do not appear to meet perimeter yard setbacks. If these structures are to remain provided documentation that they were either approved via a building permit or compliance review. If they are to remain show them on the plan and include them in the lot coverage. If they are to be removed show them on the plan as to be removed. Depending on how this comment is addressed a Zoning inspection may be added to insure that the plot plan and what is on site match.

2. Remove the setback lines and provide perimeter yard setback dimensions from the proposed structures to the applicable property lines.

3. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A. Provide dimensions from design grade to the highest point of the wall on the elevations.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
07/09/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM04905
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration

GENERAL COMMENTS:


SITE PLAN:

1. Indicate the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Show the point of connection of proposed lines to the utility service for verifying correct sizes and necessary upgrades.

FOUNDATION PLANS:

1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1.1. Include the wall section and winding stair detail on sheet A8.

FLOOR PLANS:

1. Designate windows with tempered glass within 24” of doorways, R308.4.
2. Show the location of tempered glass adjacent to stairways, R308.4.6.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.

PLUMBING PLANS:

1. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units.

ELECTRICAL PLANS:

1. Show locations of each smoke alarm. Show a smoke alarm at the first story of the stairway outside of the bedroom, R314.3.3.
2. Specify high-efficacy lamps for at least 90% of all lighting fixtures, N1104.1. Update note #15.