Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM04732
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/09/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 06/22/2021 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T21CM04732 – Porch Addition Building Plan Review (1st Review) 5428 S Monrovia Av / R-2 Zoning TRANSMITTAL DATE: 6/22/21 DUE DATE: 6/22/21 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide a complete site plan on the next submittal with accurate setbacks from the building to all property lines. The site plan should show a better view of the subject property. 2.COMMENT: Setbacks for the porch addition for an R-2 zone are 6’ or 2/3rds the height (whichever is greater) of the structure. The setbacks are measured from the property line to the posts of the porch. If you have any questions about this transmittal, Contact Iman Monshizadeh by email Iman.Monshizadeh@tucsonaz.gov or contact Elisa Hamblin, at Elisa.Hamblin@tucsonaz.gov |
| 06/28/2021 | AWARNER1 | NPPO | REVIEW | Passed | |
| 06/30/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide a means of accessing the balcony such as door with lighting or stairway with 2018 IRC compliance. |