Permit Number: T21CM04727
Parcel: 140260090

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM04727
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/10/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Show how the water pipes to the outside hand sink are to be protected from freezing. Reference: Section 305.4, IPC 2018.
2. Provide the capacity of the existing grease interceptor and verify that it meets the needs of the connected fixtures. Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson.
06/10/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change Show how adequate make-up air is to be provided to the room so that the room pressure remains essentially neutral. Reference: Section 501.4, IMC 2018.
06/10/2021 ROBERT SHERRY WATER REVIEW Completed
06/14/2021 STEVE SHIELDS ZONING REVIEW Approved
06/14/2021 SSHIELD1 ENGINEERING REVIEW Passed
06/14/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
06/16/2021 JPEELDA1 FIRE REVIEW Approved
06/28/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
07/06/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved