Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM04727
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/10/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Show how the water pipes to the outside hand sink are to be protected from freezing. Reference: Section 305.4, IPC 2018. 2. Provide the capacity of the existing grease interceptor and verify that it meets the needs of the connected fixtures. Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson. |
06/10/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Show how adequate make-up air is to be provided to the room so that the room pressure remains essentially neutral. Reference: Section 501.4, IMC 2018. |
06/10/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
06/14/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
06/14/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
06/14/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
06/16/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
06/28/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
07/06/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved |