Permit Number: T21CM04632
Parcel: 112040060

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM04632
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2021 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T21CM04632 (Project Number)
Single Family Residential addition (Project Type) (1st Review)
2617 E Glenn

TRANSMITTAL DATE: June 14, 2021

DUE DATE: June 17, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

01. COMMENT: The proposed use is single family residential, which is permitted in the R-2 zone, use specific standards 4.9.7.B.6, .9 and .10 are applicable.

02. COMMENT: Provide an elevation and measurement for the height of the wall (not the height of the building) adjacent to the western property line to determine the required setback. The setback is 6’ or 2/3 the height of the adjacent wall, the greater of which will apply, measured from the exterior wall to the property line. See UDC, Section 6.4.5, for rules of measurement of the perimeter yard.

03. COMMENT: Provide the lot coverage calculation, 70% lot coverage is the maximum permitted. Combine the area of any buildings, the vehicular use area (improve/unimproved) and any storage area, then divide these areas by the area of the lot to provide the lot coverage calculation.

If you have any questions about this transmittal, Contact Loran Shamis at Loran.Shamis@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
06/28/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM04632
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration

Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits

SITE PLAN:

1. Indicate the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1.

FLOOR PLANS:

1. Show the functional name of each proposed room and each adjacent room, R106.1.1. Identify altered doors or windows.
2. Show a ½” gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R302.6.

SECTIONS - DETAILS:

1. Show the exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5) with minimum ½” diameter anchor bolt and treated sill plates, R602.10.8 & R403.1.6. The weep screed requires a minimum 4” clearance above grade or 2” above paved areas, R703.7.2.1.

ELECTRICAL PLANS:

1. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, E3703.5.
2. Garage Receptacle Location: an outlet is required at each vehicle bay not more than 5.5 feet above the floor, E3901.9.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
06/28/2021 AWARNER1 NPPO REVIEW Passed
07/08/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. Floodplain Use Permit needs to be issued before building permit can be approved.
2. Need cost estimate of proprosed work sent to me in order to process the FUP.

Stephen Blood
(520) 837-4958