Review Date Reviewer's Name Type of Review Description Status Comments
10/17/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM04564
462 E Roger Rd
Stem Wall for Manufactured Home (2nd Review)

TRANSMITTAL October 17, 2022

This site is located in the R-2 zone (UDC 4.7.9). Manufactured Housing is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

2. This comment was not addressed. Based on the Pima County Assessor’s record map and a land split documents approved in 2001 the parcel lines shown on the site plan are not correct.

3. This comment was not addressed. Per the approved land split document there is a 15’ & 10’ ingress/egress & utility along the east property line that needs to be shown on the plan.

4. This comment was not addressed. Provide the recordation information for the 10’ utility easement that runs along the south property line, Bk 8 Pg 61.

5. This comment was not addressed. Provide the following on the required plot plan, see comment 1 above. Per UDC Article 4.9.7.B.6 the following Use Specific Standards apply. List these standards on the plan as a note and ensure that the same note is placed on the plans for the manufacture home when submitted:

Manufactured housing unit is not considered a dwelling for the purposes of this section, unless the following standards are met or a subdivision plat that has been clearly identified for manufactured housing has been approved and permits for manufactured homes have been issued for 25% or more of the lots prior to December 27, 2000:
a. It is placed on an excavated and backfilled foundation (ground set). If the home is located in a floodplain, the bottom of the lowest floor joist shall be a minimum of one foot above the 100-year/base flood elevation, and the foundation of the home shall be placed on the fill ;
b. No more than eight inches of perimeter skirting wall shall be visible from the street frontage of the property. The perimeter skirting wall shall match the exterior color of the home;
c. The exterior siding materials shall be either hardboard, vinyl, or stucco;
d. Concrete or masonry steps shall be provided for the entry on the street side of the dwelling;
e. All entry doors on the street side of the dwelling shall be inward-swinging doors; and,
f. The roofing style and materials shall be either flat roof (Pueblo), steel rib roof, or shingle or tile roof with a 3:12 roof pitch or greater. All pitched roofs, except those that are disguised by a parapet, shall have a minimum six inch eave on all sides of the dwelling.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
.