Permit Number: T21CM04363
Parcel: 13734001A

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T21CM04363
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/02/2021 ROBERT SHERRY WATER REVIEW Completed
06/03/2021 JPEELDA1 FIRE REVIEW Approved
06/11/2021 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM04363

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

STRUCTURAL REVIEW COMMENTS:
Denied
1. Verify Type of Construction of the Building. It’s called VB on Drawing C-1.
2. Detail 2 on Drawing S2 shows Pressure Treated Lumber. Verify if it’s in consistent with Combustible Material allowed
in Type II construction as shown in Section 603 of IBC 2018.

BUILDING REVIEW COMMENTS:
Denied
1. Provide detailed square footage breakdown of remodeled square footage that includes occupant load calculations

MECHANICAL REVIEW COMMENTS:
Approved

ELECTRICAL REVIEW COMMENTS
Approved

PLUMBING REVIEW COMMENTS:
Conditionally Approved
419.6 Automatic faucets. Lavatories installed in all buildings other than R3 occupancies, individual units of R2 occupancies,
or International Residential Code structures shall be provided with automatic faucets dispensing a maximum of 0.25 gallon
per metering cycle.
06/15/2021 STEVE SHIELDS ZONING REVIEW Approved
06/15/2021 SSHIELD1 ENGINEERING REVIEW Passed
06/15/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
06/15/2021 NGARCIA3 OUT TO CUSTOMER Completed