Permit Number: T21CM04278
Parcel: 12801001B

Address:
170 S WILMOT RD

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T21CM04278
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2021 JVINCEN1 FIRE REVIEW Approved
06/09/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet A1: Please provide a Code Analysis on this sheet indicating the square footage of the patio addition, the total square footage of the existing building + the patio addition, the number of occupants for the patio addition, the total number of occupants for the existing building + the patio addition, the construction type for the existing building and the patio addition, and the required plumbing fixtures for the total number of occupants for the existing building + patio addition.
2. Sheet A1; Enlarged Patio Plan: A plan note indicates the awning structure is not included in this contract. Will it be a deferred submittal to this permit, or a separate permit independent of this permit? Please add this information to the plan note.
3. Sheet A1; Detail 2 (Concrete Note): Please indicate on this detail the reinforcement size, quantity, and spacing for the concrete slab and turn-down edge.
4. Sheet A1; Detail 2 (Concrete Note): Please add new details indicating the dowels of the new concrete slab and turn-down edge into the existing sidewalk and building. Indicate the dowel size, spacing, quantity, and minimum embedment depth into the existing concrete.
5. General: Please provide written responses to all review comments.
06/11/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM04278
170 S Wilmot Rd
New Outdoor Seating

TRANSMITTAL: June 11, 2021
This site is located in the C-1 zone (UDC 4.7.20). Food Service is a permitted use in this zone (Table 4.8-4). See Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O.

1. Until DP21-0128 is approved Zoning cannot approve the patio plan.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
07/02/2021 LOREN MAKUS ENGINEERING REVIEW Passed
07/15/2021 LSHAMIS1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
07/15/2021 VVERA1 OUT TO CUSTOMER Completed