Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM04278
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 06/09/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A1: Please provide a Code Analysis on this sheet indicating the square footage of the patio addition, the total square footage of the existing building + the patio addition, the number of occupants for the patio addition, the total number of occupants for the existing building + the patio addition, the construction type for the existing building and the patio addition, and the required plumbing fixtures for the total number of occupants for the existing building + patio addition. 2. Sheet A1; Enlarged Patio Plan: A plan note indicates the awning structure is not included in this contract. Will it be a deferred submittal to this permit, or a separate permit independent of this permit? Please add this information to the plan note. 3. Sheet A1; Detail 2 (Concrete Note): Please indicate on this detail the reinforcement size, quantity, and spacing for the concrete slab and turn-down edge. 4. Sheet A1; Detail 2 (Concrete Note): Please add new details indicating the dowels of the new concrete slab and turn-down edge into the existing sidewalk and building. Indicate the dowel size, spacing, quantity, and minimum embedment depth into the existing concrete. 5. General: Please provide written responses to all review comments. |
| 06/11/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM04278 170 S Wilmot Rd New Outdoor Seating TRANSMITTAL: June 11, 2021 This site is located in the C-1 zone (UDC 4.7.20). Food Service is a permitted use in this zone (Table 4.8-4). See Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. 1. Until DP21-0128 is approved Zoning cannot approve the patio plan. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 07/02/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 07/15/2021 | LSHAMIS1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/15/2021 | VVERA1 | OUT TO CUSTOMER | Completed |