Permit Number: T21CM04242
Parcel: 129021250

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM04242
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2021 SBLOOD1 ENGINEERING REVIEW Passed
06/07/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM04242
TRANSMITTAL: June 7, 2021
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the wall, see Unified Development Code (UDC) Article 6.4.5.b & Figure 6.4.5-A.

As height dimensions to the highest point of the wall were not provided Zoning has use a measurement function in Bluebeam to determine perimeter yard setback dimensions.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).
1. Based on a wall height of less than 9’-0” the required perimeter yard setback from the proposed carport to the east and west property line is 6’-0”, proposed setback to the east property line is 3’-0” and to the west property line is 3’-10”.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).
Based on a wall height of less than 13’-4” the required front street perimeter yard setback from the proposed carport to the street property line is 20’-0”, proposed setback to the street property line is 17’-0”

2. The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 3.11.1.B.4). In a developing area, the minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).
3. The porch shown on the east side of the existing dwelling shows up on aerial photo’s some time after 2008, provide permit documentation for this structure.

If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.
06/16/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside. Provide notation for compliance with R302.1 (City of Tucson Amended) for providing 1 hour rating on the underside of the overhang.
06/28/2021 AWARNER1 NPPO REVIEW Passed