Permit Number: T21CM03841
Parcel: 116170650

Address:
760 N GRANDE AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM03841
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/14/2021 AWARNER1 NPPO REVIEW Passed
05/26/2021 PCAMARE1 ENGINEERING REVIEW Passed
06/01/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM03841
760 N Grande Ave
New detached carport & site fence and wall (1st Review)

TRANSMITTAL DATE: June 1, 2021

This site is located in the C-1 zone (UDC 4.7.20). A single-family residence is a permitted use in this zone (Table 4.8-4).

1. Per Unified Development Code (UDC) Table 6.3-4.A: DIMENSIONAL STANDARDS FOR THE C-1, C-2, C-3, OCR-1, & OCR-2 ZONES, C-1 Zone, Res Use to Res Zone the required perimeter yard setback from the proposed carport to the east property line is 10’-0” or ¾ the height of the exterior wall. Based on a wall height of less than 13’-4” the required perimeter yard setback to the east property line is 10’-0”, proposed is 2’-0”. At a minimum a neighbor signoff is required from the owner of the property at 1114 W Erie St. If you are unable to obtain a neighbor signoff a Design Development Option (DDO) must be submitted and approved.
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

2. The maximum height of a wall within the perimeter yard setback is 6’-0”, see UDC Article 6.6.2.I this height measurement includes the cap block.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov
06/03/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM03841
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL:

1. A Carport may extend into the 3-foot fire separation distance with R302.1 (City of Tucson Amended) compliant 1 hour rated barrier near the shared private property line running the full length of the roof. Show one-hour fire-resistive construction in compliance with IBC Table 721.1(2) providing a fire barrier at the south Carport wall.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review