Permit Number - T21CM03672
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2022 STEVE SHIELDS ZONING REVIEW Approved
07/14/2022 VFLORES1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Reqs Change Unit number for proposed ADU is required. Please contact Pima County Addressing Phone # 520-724-9512, Email: Addressing@pima.gov
07/25/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T21CM03672

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Update the design wind speed in the general structural notes sheet S1.0 to indicate a basic wind speed of 115 mph. 2018 IRC table R301.2(1) as amended. Modify any structure accordingly.
2. Indicate that the soil under the slab and around the footings will be treated for termites prior to the pouring of the concrete. 2018 IRC R318.


BUILDING REVIEW COMMENTS:
Denied
1. Update the sheet index on sheet A1 to include sheet S3.1.
2. Indicate on the site plan that the new pool, spa, and other components that are not included with this submittal will be under separate permit or indicate them as “future” work.
3. Provide a handrail detail for the stairs on the drawings. Note 8 on sheet A5 provides information on the size of the handrail, but no detail. The floor plan note on sheet A3 indicates to consult the Architect.
4. Clarify the work to be done in the basement. The basement plan keynote 4 on sheet A3.1 indicates to seal the basement from the crawlspace and to provide an option for an access hatch. Indicate how the basement is to be sealed and clarify if the existing crawl is vented or is conditioned space. If there is not to be access through the existing basement, indicate where the access will be. Detail 110 on sheet S3.0 indicates the crawl space has an existing finished floor, although the building sections appear this to be unfinished.
5. Indicate on the drawings that a permanent certificate shall be posted that contains the predominant R values of the insulation, U factor and SHGC of the windows and skylights, and the types of an efficiencies of heating cooling and service water heating equipment. It shall also indicate the results from any required duct system and building envelope testing if required. 2018 IECC R401.3.


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Denied
1. Indicate on the electrical drawings that all work shall be done in compliance with the adopted codes as amended by the City of Tucson. The electrical notes on sheet E1.1 only indicates Pima County.
2. Correct the key notes on sheets E1 and E1.1 to indicate a minimum of 90% of all lighting fixtures in the dwelling will contain high-efficacy lamps. 2018 IECC R404.1.
3. Add to the electrical note 2 on sheet E1.1 that all smoke detectors shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4.
4. Indicate the location of carbon monoxide detectors on the drawings. Carbon monoxide detectors shall be installed outside of each sleeping area in the immediate vicinity of the bedrooms. 2018 IRC R315.3. Carbon monoxide devices shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined.


PLUMBING REVIEW COMMENTS:
Denied
1. Note on the drawings that all plumbing fixtures will be low flow type. Toilets are required to be 1.6 gallons per flush or less, and showerheads and faucets are to not exceed 2.5 gallons a minute. Ordinance 7178.
2. Note on the drawings that a water hammer arrestor shall be installed where quick closing valves are utilized. 2018 IPC 604.9.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
08/08/2022 JPEELDA1 FIRE REVIEW Approved