Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM03575
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/25/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM03575 6412 E Shepherd Hills 2nd Dwelling Unit Attached to Existing Garage TRANSMITTAL: May 17, 2021 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.1 - .9, & .11. 1. Provide a setback dimension from the post supporting the porch to the street property line to the south. 2. Provide a full floor plan for the existing dwelling as the number of bedrooms in this unit will dictate the total number of vehicle parking spaces required. Per Unified Development Code (UDC) Article 4.9.7.B.7 for any new single-family dwelling in the R-1 zone with five bedrooms , three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms , and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard . A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. The required vehicle parking may not be located in the area between the existing and proposed dwelling units and the south street property line. 3. Provide fully dimensioned elevations so the perimeter yard setback requirements can be verified. 4. Per UDC Article 7.9.7.B.3 One dwelling must be at least 25% smaller than the other dwelling. For this proposed conversion the total square footage includes the existing garage. Clearly demonstrate on the plan that this requirement is met. 5. As this dwelling unit is a conversion of a storage addition, T21CM01296, impact fees apply. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 05/25/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 05/25/2021 | AWARNER1 | NPPO | REVIEW | Passed | |
| 05/25/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM03575 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Each dwelling unit requires a separate Pima County assigned street address, R319 Show all dwelling addresses on the site plan. GENERAL COMMENTS: 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. 2. A new dwelling unit requires collection of development impact fee when the building permit is processed, City of Tucson Ordinance #11203. FLOOR PLANS: 1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate water meter size. 2. Update keynote #9 sheet A3 showing a gas water heater since sheet E1 shows an electrical unit. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the system and appropriate flow rate setting on the plans. A one bedroom dwelling under 1500 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Show service meter on a Riser Diagram for each dwelling (dual pack) with a single drop from the utility. A feeder is required for serving a distribution panel for each dwelling, NEC 225.30 and E3403. 2. Coordinate the service requirement with TEP. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
| 06/02/2021 | JPEELDA1 | FIRE | REVIEW | Approved |