Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM03545
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Install the proposed vacuum relief valve for the water heaters per the manufacturer’s listing information, i.e. on the cold water supply to the water heater. Reference: Section 303.2, IPC 2018 [Initial comment: Provide an approved vacuum relief valve for the scheduled bottom-fed water heater that is located above the fixture outlets. Reference: Section 504.2, IPC 2018.] |
| 07/15/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 07/15/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/21/2021 | DBENOIT1 | APPROVAL SHELF | Completed |
| 07/21/2021 | DBENOIT1 | OUT TO CUSTOMER | Completed |
| 07/21/2021 | DBENOIT1 | REJECT SHELF | Completed |