Permit Number: T21CM03545
Parcel: 14022001A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM03545
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Install the proposed vacuum relief valve for the water heaters per the manufacturer’s listing information, i.e. on the cold water supply to the water heater. Reference: Section 303.2, IPC 2018 [Initial comment: Provide an approved vacuum relief valve for the scheduled bottom-fed water heater that is located above the fixture outlets. Reference: Section 504.2, IPC 2018.]
07/15/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
07/15/2021 STEVE SHIELDS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/21/2021 DBENOIT1 APPROVAL SHELF Completed
07/21/2021 DBENOIT1 OUT TO CUSTOMER Completed
07/21/2021 DBENOIT1 REJECT SHELF Completed