| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 05/10/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM03535 5490 S Oak Ridge Dr Detached Ramada (1st Review) TRANSMITTAL DATE: May 10, 2021 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10 1. Provide a residential plot plan that meets all requirements shown at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. Per Unified Development Code (UDC) Article 6.4.5.C.1.b Where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet. That said it does not appear that the proposed ramada meets the minimum 10’ side street setback. Provide a side street setback dimension on the plan. To reduce this setback will require a Design Development Option (DDO). DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. 2. Provide a setback dimension from the proposed ramada to the southwest property line. The required perimeter yard setback is 6’-0” or 2/3 the height of the exterior wall, greater of the two. You can reduce this setback one of two ways. Per UDC Article 6.6.2.D you can request a setback waiver from the adjacent property owner. To do this provided the following text on the plot plan and have the adjacent neighbor sign an date. My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ The other option would be the DDO. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
| 05/10/2021 | AWARNER1 | NPPO | REVIEW | Passed | |
| 05/24/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed |