Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM03508
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/29/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify that the point of connection to the existing 3-inch building sewer (building drain?) is downstream of the trap for the existing floor drain. Reference: Section 107.2.1, IBC 2018. 2. Provide a full-open valve for the water service at the entrance to the flexmod. Reference: Section 606.1(2), IPC 2018. |
| 04/29/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 04/29/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 04/29/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/05/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 05/11/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheets A000 and A020: Drawings must be sealed, signed, and dated by a registered design professional per the IBC Section 107.1. 2. Sheet A000; Project Description: This description indicates a new 300 SF Flexmod Unit. Please indicate if this is a premanufactured unit, and provide cut sheets and sections as required for the unit construction and connection to a foundation or slab. Provide structural calculations for the unit, foundation, and holddowns as required. 3. Sheet A020; Site Plan Keynotes and Section: Keynote 8 and the associated section indicate an 8' existing CMU with a 2' screen extension. The detail indicates the wrought iron fence extends 3'-6" above the existing CMU wall. Please coordinate. 4. Sheet A020; Code Analysis: The analysis should be updated to the 2018 IBC for this project. 5. General: Please provide written responses to all review comments. |
| 05/20/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. Could not locate Lighting and power plan ‘E101’ in the plan set as stated per GENERAL NOTE #1 on plan sheet ‘E1’. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2012 Tucson/Pima County Outdoor Lighting Code, City of Tucson Commercial Plan Submittal Requirements |
| 05/27/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM03508 6464 E Tanque Verde Rd Site Fence & Accessory Structures (Flexmode) TRANSMITTAL: May 27, 2021 This site is located in the C-2 zone (UDC 4.7.21). Medical Marijuana Dispensary is a permitted use subject to Use Specific Standard 4.9.9.E.1. 1. As site work is proposed, fencing and flexmode additions a Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 shall be submitted and approved prior to approval of this plan. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 07/14/2021 | LSHAMIS1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed |