Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM03504
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/13/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM03504 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the structure’s original permit number or show alterations for achieving code compliance. FLOOR PLANS: 1. Show one-hour fire-resistive framed construction in compliance with IBC Table 721.1(2). Update the non-compliant notation of “1/2” T1-11” at detail #2 on F-1. SECTIONS - DETAILS: 1. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5) with minimum ½” diameter anchor bolt and treated sill plates, R602.10.8 & R403.1.6. This may require a concrete stem when the floor is less than 6” above grade. Update detail #1 on F-1. PLUMBING PLANS: 1. Provide devices rated for application, G2406.3. A two-way valve is not appropriate for building drainage. Also, gray water may be discharged within 5 feet of a building foundation. Remove the gray water valve. ELECTRICAL PLANS: 1. Interior alterations require the installation of smoke alarms at existing bedrooms, R314.2.1. Provide notation if the smoke alarms are existing or proposed. 2. Provide a disconnect switch with clear working space of 30” wide x 36” deep, E3405.2. Relocate the mini split switch to a location where the required space is on the dwelling property. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |