Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T21CM03490
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/02/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM03490 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Refer to Drawing DT1.1, Foundations are shown below 3 Steel Columns and No Foundations provided for 5 Steel Columns supporting the canopy. Verify, make revisions and resubmit. BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Denied 508.1.2 Air Balance - Design plans for a facility with a commercial kitchen ventilation system shall include a schedule or diagram indicating the design outdoor air balance. The design outdoor air balance shall indicate all exhaust and replacement air for the facility, plus the net exfiltration if applicable. The total replacement air airflow rate shall equal the total exhaust airflow rate plus the net exfiltration. Sheet M2.1 Demonstrate compliance Section 403.3.1.5 Balancing. REVISE Section by DELETING the second sentence which reads “Ventilation systems shall be balanced by an approved method” and REPLACING it with the following: Ventilation systems shall be balanced by individuals holding current certification from the Associated Air Balance Council (AABC), the National Environmental Balancing Bureau (NEBB) or other approved agencies. Final reports shall be provided to the engineer of record and the code official prior to the issuance of a certificate of occupancy. ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Approval Pending NOTE: Every effort has been made to identify code violations. Any oversight by the reviewer shall not be considered as authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The designer is responsible for following all applicable federal, state, and municipal codes and ordinances AND WILL BE FIELD VERIFIED. |
| 09/09/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 09/09/2021 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 09/14/2021 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Comment not resolved. The riser diagram on P3.5 and detail 6P4.1 still show a double check valve assembly located inside of the building while the civil utility plan C5.0 shows the location of the required reduced pressure backflow assembly by the water meter. First, do you really want to have both backflow assemblies and their pressure drops? Second, a development plan is not to be used for construction or modification of on-site utilities (e.g. water service to buildings, building sewers, site lighting, electrical service to buildings, etc.). The construction of the on-site utilities may be included with the permit for constructing the building or as a separate permit. If you are including the civil plan C5.0 with this permit, it may not be marked as "FOR REFERENCE ONLY" (a grading and paving permit is essentially a license to move dirt). [Initial comment: Reduced pressure backflow prevention assemblies are required to be installed directly after the water meter for buildings that have food service facilities and in locations accessible to Tucson Water. (See the development package, DP21-0029, for the actual location of the water meter and the reduced pressure backflow preventer.) Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, http://www.tucsonaz.gov/files/water/docs/backflow-ordinance.pdf.] |
| 09/20/2021 | SBLOOD1 | ENGINEERING | REVIEW | Approved |