Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM03393
Parcel: 11807002J

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM03393
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2021 ROBERT SHERRY WATER REVIEW Completed
04/30/2021 SBLOOD1 ENGINEERING REVIEW Approved
05/18/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
05/18/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM03393
2002 S Mission Rd
Addition to existing Fire Station (1st Review)

TRANSMITTAL DATE: May 18, 2021

This site is located in the R-2 zone (UDC 4.7.9). Protective Service (government owned and operated only) is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standard 4.9.13.F.

1. The building plans have been reviewed for compliance with DP20-0223 and although it appears that the building plans match the DP until the DP is approved Zoning cannot approved the building plans.

If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.
05/18/2021 SAFEBUILT 2ND PARTY REVIEW REVIEW Approv-Cond Activity Number: T21CM03393

GENERAL:
o Provide written responses to all review comments.
o Provide a complete plan set.
o Provide additional documents as requested by review staff.

STRUCTURAL REVIEW COMMENTS:
Conditionally Approved
1. Geotechnical Report for the proposed building per International Building Code 2018, Section 1803.1 is not provided. Inspector to verify Foundation info on Drawing S1.0 and the Geotechnical Report. 2. Roof drainage and secondary drains are to comply with IBC 1502.1. 3. Refer Drg. S1.0. Loads: Ultimate wind speed is correctly called as 115 mph. Design wind speed (Vasd) is called 85 mph. Verify and make corrections as needed.

BUILDING REVIEW COMMENTS:
Approved

ELECTRICAL REVIEW COMMENTS
Conditionally Approved
E4.0 ONE LINE DIAGRAM, PANEL SCHEDULES AND CALCULATIONS: No electrical issues. Arc flash calculations for Panels L1 and L2 are reversed. No effect on design.

MECHANICAL REVIEW COMMENTS:
Conditionally Approved
NOTE: Every effort has been made to identify code violations. Any oversight by the reviewer shall not be considered as authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The designer is responsible for following all applicable federal, state, and municipal codes and ordinances.

PLUMBING REVIEW COMMENTS:
Conditionally Approved
City of Tucson Amendments to the 2018 International Plumbing Code Chapter 1 SCOPE AND ADMINISTRATION. DELETE Chapter 1 with the exception of Section 107. (Deleted sections are administered by 2018 IBC, Chapter 1) Section 305.4.1 Sewer depth. INSERT [NUMBER] as "12" in both locations. Section 312.1 Required tests. REVISE section by DELETING the last two sentences of the first paragraph which read "After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain whether the pressure has reached all parts of the system".
05/18/2021 JPEELDA1 FIRE REVIEW Reqs Change Code Summary Under Fire Protection: remove the fire sprinkler notes if not fire sprinklering, remove the emergency shut off if not being used, remove hood notes if not being used.
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033