Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2021 JGARCIA1 NPPO REVIEW Passed
04/16/2021 SBLOOD1 ENGINEERING REVIEW Passed
04/19/2021 NICHOLAS ROSS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL


FROM: Samuel Rogers, Planner
PROJECT:
T19CM05922, 4233 E Lester
Garage Addition
TRANSMITTAL: 8/20/2019
COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The wall height it 8' requiring a 6' set back. The proposed setback is 5-3'.

Accessory structures are required to be 50% the size of the principle structure. The proposed structure exceeds 50% of the principle structure's size.

A previous DDO was denied per T19SA00147.
04/19/2021 NICHOLAS ROSS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL


FROM: Samuel Rogers, Planner
PROJECT:
T19CM05922, 4233 E Lester
Garage Addition
TRANSMITTAL: 8/20/2019
COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The wall height it 8' requiring a 6' set back. The proposed setback is 5-3'.

Accessory structures are required to be 50% the size of the principle structure. The proposed structure exceeds 50% of the principle structure's size.

A previous DDO was denied per T19SA00147.
05/04/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3.

Show Bathroom receptacles on a separate 20 AMP circuit (dedicated) with outlets at no other location, E3703.4 and E3901.6.

Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.