Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM03113
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM03113 10 E Broadway Bl Conversion from Office to Residential TRANSMITTAL: May 10, 2021 This site is located in the OCR-2 zone (UDC 4.7.27). Multifamily Development is a permitted use. 1. Until this plan is approved by the Design Professional Zoning cannot approve. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 05/10/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 05/10/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Trash Chutes Per: IBC 713.13.1 not allowed unless you have a 45 minute rating. Plans call for Smoke Guard 400 but that is only a smoke curtain. If the Smoke Guard is to be used it shall be the 2100 or 2500 model. Please show the two way communication for the elevator on the exterior and the communication system for the interior of the elevator per the 2018 IBC. Plans shall show that the building shall be tested for Emergency Responder Radio Coverage and the results provided to TFD. |
| 05/10/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM03113 GENERAL: o Provide written responses to all review comments. o Provide a complete plan set. o Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Refer Drawing S2.1, Roof Framing Plan. Check the load carrying capacity of Holo Core Planks supporting New RTU's weighing 750#, 800# and 2400#. Also check the beams supporting these planks and submit the calculations. 2. The Professional Engineer Stamp on the Drawing shows that it is expiring 12/31/2020. Submit documentation that it has ben renewed. 3. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona er Section 107.1 of International Building Code 2018. BUILDING REVIEW COMMENTS: Denied 1. The exit in the center of the building does provide protection all the way to the exit discharge. Once exiting the protected stair well and rated enclosure, the occupant is in an unprotected foyer area. Once entering the exit the level of safety cannot be decreased. 2. The second accessible exit is not shown. If it is through the enclosure and foyer the same issue applies as above. Additional exit lighting may be required. 3. Provide calculations showing the amount of ADA units is appropriate in compliance with Section 1107.6.2.2.1 and 1107.6.2.2.2. Which unit is Type A? 4. Show the accessible route from site arrival to the accessible units. ELECTRICAL REVIEW COMMENTS Denied E1.0 ELECTRICAL SYMBOLS & LIGHT FIXTURE SCHEDULE: No electrical issues E1.1 ELECTRICAL SYMBOLS & LIGHT FIXTURE SCHEDULE: No electrical issues E1.2 ELECTRICAL DETAILS: No electrical issues E1.3 PANEL SCHEDULES: No electrical issues E1.4 FEEDER DIAGRAM: No electrical issues E1.5 FIRE ALARM DETAILS & EMERGENCY INTERCOM DETAIL: No electrical issues E2.1 BASEMENT AND GROUND LEVEL POWER PLAN: No electrical issues E2.2 2ND AND 3RD LEVEL POWER PLAN: No electrical issues E2.3 4TH LEVEL AND ROOF POWER PLAN: No electrical issues E2.4 GROUND LEVEL APARTMENT ELECTRICAL PLANS: No electrical issues E2.5 2ND, 3RD & 4TH LEVEL TYPICAL APARTMENTS ELECTRICAL PLANS (SOUTH): No electrical issues E2.6 2ND, 3RD & 4TH LEVEL TYPICAL APARTMENT ELECTRICAL PLANS (NORTH): No electrical issues E3.1 BASEMENT AND GROUND LEVEL LIGHTING PLAN: No electrical issues E3.2 2ND AND 3RD LEVEL LIGHTING PLANS: No electrical issues E3.3 4TH LEVEL AND ROOF LIGHTING PLANS: No electrical issues E4.1 BASEMENT AND GROUND LEVEL SPECIAL SYSTEM PLANS: No electrical issues E4.2 2ND AND 3RD LEVEL SPECIAL SYSTEM PLANS: No electrical issues E4.3 4TH LEVEL AND ROOF SPECIAL SYSTEM PLANS: No electrical issues MECHANICAL REVIEW COMMENTS: Approved PLUMBING REVIEW COMMENTS: Approved |
| 05/10/2021 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 05/14/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 07/21/2021 | MGAYOSS1 | DESIGN PROFESSIONAL | REVIEW | Denied | 7/21/21 - Review by MarĂa Gayosso, for compliance with IID-15-09 West Pointe. Met with applicant and Design Professional on 7/8/21 to discuss proposal, Applicant informed property owner found a tenant that wants to take over the entire ground floor for retail and restaurant uses. Requested applicant that, when revised CDs are resubmitted, to clearly indicate in a letter and on the drawings if any exterior modifications to the structures (on any floor, not just on the ground floor) will need to be reviewed by the Historic Preservation Officer and the Design Professional. At that point it will be decided if the proposed changes will incur into a major a minor IID/HPZ review process. |