Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM03108
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/21/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
04/26/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
04/28/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM03108 GENERAL: o Provide written responses to all review comments. o Provide a complete plan set. o Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Verify the Roof Joists and Joist Girders are capable of supporting additional loads from the new condenser units being added at the roof. Support your response with Structural Calculations. 2. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. BUILDING REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Denied E1 LIGHTING PLAN: No electrical issues E1.1 ENLARGED LIGHTING PLANS AND SCHEDULE: No electrical issues E2 POWER PLAN: No electrical issues E2.1 POWER DROP PLAN: No electrical issues E2.2 ENLARGED POWER PLANS: No electrical issues E3 ELECTRICAL DETAILS: No electrical issues E4 PANELBOARD SCHEDULES: No electrical issues E4.1 PANELBOARD SCHEDULES: No electrical issues EPH1 PHARMACY ELECTRICAL PLAN: No electrical issues RE1 REFRIGERATION ELECTRICAL PLAN: No electrical issues GE1 GROCERY LIGHTING PLANS: No electrical issues GE2 GROCERY POWER PLANS: No electrical issues MECHANICAL REVIEW COMMENTS: Denied 1. Show rooftop gas equipment types, calculations and locations per 2018 IMC 301. 2. Provide rooftop equipment utility connection information per 2018 IMC 301. 3. Show all new equipment refrigeration types and locations per 2018 IMC 1103. 4. Provide existing and new duct work insulation types and locations per 2018 IMC 604. 5. Show existing and new equipment shut down device locations per 2018 IMC 606. 6. Provide existing and new exposed duct work support spacing per 2018 IMC 603. 7. Show rooftop equipment stands fire resistant construction details per 2018 IBC 601. PLUMBING REVIEW COMMENTS: Approved with comments: Floor drains must have deep seal traps or trap primers and fixtures must have air gaps per plumbing code.., McGraw-Hill, Inc., page 1028. o A minimum of 25% storage is required for floatable fats, oil and grease and settled solids is required for gravity grease interceptors. o The minimum sized GGI to be installed shall be 300 gallons. |
05/05/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
05/05/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
05/05/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved |