Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM03016
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/15/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
04/26/2021 | CTREVIL1 | ZONING | REVIEW | Passed | |
04/26/2021 | CTREVIL1 | ENGINEERING | REVIEW | Passed | |
04/27/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM03016 GENERAL: o Provide written responses to all review comments. o Provide a complete plan set. o Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: APPROVED BUILDING REVIEW COMMENTS: Denied 1. Phase 2 Sheet 13, Ship Ladder Assembly: The treads and risers of the ship ladder do not the meet the minimum requirements of 1011.15.2 2. Phase 2 Sheet 13, Ship Ladder Assembly: It appears that distance between the handrails do not comply with Section 1011.15 3. All platforms that are 30" above the ground is required to have guards in compliance with Section 1015. It appears that are some platform that will not have guards in some places. Provide clarification for the areas of the platforms marked with an asterisk. 4. Phase 1 Sheet 14, Ship Ladder Assembly: The treads and risers of the ship ladder do not the meet the minimum requirements of 1011.15.2 5. Phase 1 Sheet 14, Ship Ladder Assembly: It appears that distance between the handrails do not comply with Section 1011.15 6. Provide a detailed code analysis of the project that includes occupancy classification, construction types and occupancy load calculations. Also, include a list of the new platforms that include square footage of each. Electrical Review DENIED 1 00124-001001 TITLE PAGE: Set needs a cable schedule to identify feeders to the wire size/ratings for the conductors feeding into and out of the 1000 amp Main Distribution Panel and sub feeder circuit breakers. Cannot determine if the Circuit Breakers protect the cables/conductors as they are not identified. Need to also provide information on grounding for all of the major panels. 19 00124-101301 CDP01 THREE LINES: Cannot determine if feeders for 1000-amp Main Disconnect are acceptable. Need to call out conductors and raceway. 20 00124-001201 CP01 SINGLE LINES: No Electrical issues. Settings on CBs seem optimistically accurate. Most CB selections do not have the stated resolution. MECHANICAL REVIEW COMMENTS: NA PLUMBING REVIEW COMMENTS: NA |