Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T21CM02982
Parcel: 110162290

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM02982
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/21/2021 NMARTEL1 ZONING REVIEW Approved
04/21/2021 LOREN MAKUS ENGINEERING REVIEW Approved
04/21/2021 SSHIELD1 NPPO REVIEW Passed
04/27/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Clarify the connection to bearing wall or beam at the dwelling. Detail #5 shows a 3 x 6 ledger that is not showing continuous fastening to a bearing wall on the Framing Plan. Update the Framing Plan extending the rafters to the dwelling wall or show a beam size with support connection points rather than a ledger.