Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM02892
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/13/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
04/13/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
04/13/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
04/14/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
04/20/2021 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
04/20/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A000; Building Codes: Please replace the 2010 ADA Standards with the 2009 ICC/ANSI A117.1. 2. Sheet A001; ADA Seating Requirements: The minimum clearance at ADA tables references 10/A500. Please revise that reference. 3. Sheet A200; Floor Plan Legend: The new wall indicates 'new 2x4 stud wall'. Please revise that note for metal studs. 4. Sheet A500; Detail 1: The title indicates 3 5/8" Stud Partition, but the stud note indicates 6" 20 gauge metal studs. Please coordinate. 5. Sheet A500; Detail 3: The structural member at the top of the operable wall panel indicates 'Structural Member not by Panel Fold'. Please provide a structural calculation for that member, and indicate the member size on a detail, including member bracing as required. 6. General: Please provide written responses to all review comments. |
04/27/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. Designate branch circuit numbers and panel for all power and lighting, and any other electrical devices or equipment on the electrical plans. NEC 408.4. Show all new or relocated luminaires on the power and or lighting plans. Show the location of the Loadcenter or Panel on the electrical plan. Provide a complete panel schedule including load calculations for added electrical loads. Provide a complete luminaire schedule if new lighting is proposed. If new lighting is proposed, provide 2018 IECC compliance. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC. |
04/28/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
05/03/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved |