Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM02842
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/14/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
04/14/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
04/23/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
04/26/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
04/26/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
04/27/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM02842 GENERAL: o Provide written responses to all review comments. o Provide a complete plan set. o Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: N/A BUILDING REVIEW COMMENTS: Denied 1. The occupancy classification listed is not correct. It's listed as a B occupancy. This occupancy most resembles an F-1 occupancy as it appears to manufacture optical goods. Correct and correlate with all other sheets. 2. As this is an F-1 occupancy a complete equipment layout is required that clearly shows a delineated egress paths. 3. Provide clarification on how this occupancy interacts with the rest of the building. The cover sheet states that it is nonseparated mixed use. Provide evidence that this tenant space complies with section 508. 4. This occupancy is required to be protected by a NFPA 13 sprinkler system per Section 903.2.4. 5. The breakroom occupant load is not calculated. Provide a proper occupant load calculation for the breakroom. 6. The floor plan indicate wall type tags. No wall types are provided. Provide wall types along with associated wall details. 7. Provide a separate demolition plan and new framing plan. ELECTRICAL REVIEW COMMENTS Approved MECHANICAL REVIEW COMMENTS: Denied 1. The sheet index does not list does not contain all of the mechanical sheets provided in the mechanical set. Multiple versions of the same sheet exist. Coordinate all drawings and resubmit. 2. The same details are on multiple pages. The mechanical set needs to be completely correlated and organized. 3. Provide a more detailed return air plenum that provides all appropriate details. PLUMBING REVIEW COMMENTS: APPROVED |