Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM02588
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/05/2021 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 04/05/2021 | JGARCIA1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 04/07/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 04/19/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 04/23/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 04/27/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM02588 GENERAL: o Provide written responses to all review comments. o Provide a complete plan set. o Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: NA BUILDING REVIEW COMMENTS: Denied 1. The exit door located in the kitchen cannot be used as one of the required exits. Egress cannot travel through kitchens. The door is currently labeled as an exit. 2. The swing of the door of the walk in cooler encroaches too far into a means of egress. 3. The double swing door adjacent to the exit, potentially encroaches too far into the door way of the exit. 4. Provide information on the tenant separation wall. Depending on the occupancy classification, the wall may require a fire resistance rating per T508.4. 5. Provide a comprehensive egress plan that shows the separation of exit dimensions, travels distances, etc. 6. Show the accessible route in the building. 7. No door schedule provided. Provide a comprehensive door schedule. Electrical Review DENIED 1. If the kitchen exit door is going to be used as an exit and satisfy the other comments, additional exit lighting will be required in the kitchen area. MECHANICAL REVIEW COMMENTS: APPROVED PLUMBING REVIEW COMMENTS: APPROVED |