Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T21CM02467
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/25/2021 JVINCEN1 FIRE REVIEW Approved
04/14/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. General: The Site Plan must meet the applicable requirements per the IBC Section 107.2.6.
2. General: The submittal documents must meet the applicable requirements per the IBC Section 107. Include a Code Analysis on the drawings, indicating the Occupancy Classification, Construction Type, SF, Occupant Load, Plumbing Fixture Requirements, Means of Egress, Allowable Height and Area, Fire Protection, and Accessibility Requirements.
3. General: Please indicate on the drawings current building codes and editions used for this submittal.
4. General: All submittal drawings, specifications, and calculations must be prepared by a registered design professional per the IBC Section 107.1.
5. General: The quonset structure requires structural calculations, structural drawings indicating member sizes, general structural notes with material strengths, and design loads, prepared by a registered design professional.
6. General: The quonset drawing indicates the containers supporting the new structure are 'by others'. Those containers and their foundations must be designed for this submittal, with structural calculations and details provided by a registered design professional.
7. General: Please provide a Special Inspections Certificate with Parts A and B completed. This form may be found at www.tucsonaz.gov/PDSD.
8. General: Please provide written responses to all review comments.
04/16/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change A development package is required.
04/20/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
04/20/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM02467
3910 N Runway Dr.
New Building

TRANSMITTAL: April 20, 2021
This site is located in the I-1 zone (UDC 4.7.29).

1. As a new building is proposed for this site a Development Package (DP), commercial site plan, is required. This DP shall meet the requirements of Administrative Manual 2-06: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8283, and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp.
This development package shall be submitted and approved prior to approval of the building plans.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.