Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM02451
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 04/08/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM02451 510 E 4th St. Re-shingle Roof TRANSMITTAL: April 8, 2021 COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. Historic review required for re-shingle. Historic application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf. Historic review is a separate submittal and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Historic Review”. If you have any questions about this transmittal, please contact Elisa Hamblin at ElisaHamblin@tucsonaz.gov. |
| 04/08/2021 | STEVE SHIELDS | ZONING | REVIEW | Passed | |
| 04/08/2021 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 04/13/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM02451 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: 1. Show the location of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. FOUNDATION PLANS: 1. Show exterior footings at least 12” below the undisturbed ground surface, R403.1.4. STRUCTURAL PLANS: 1. Provide a complete roof framing plan with beams and rafters sized with appropriate load carrying capacity, R301.1. SECTIONS - DETAILS: 1. Provide a complete cross-section detail from foundation to roof assembly attachment to the dwelling with size of each component, R106.1.1. MECHANICAL PLANS: 1. Clarify the location of cooler ducts (exposed, within chase or exterior), N1103.2.3. 2. Provide an equipment specification list including the evaporative cooler capacity, M1302.1. ELECTRICAL PLANS: 1. Show the mast height on the electrical riser diagram providing 8’ clearance above the Porch roof, E3604.2.1. 2. Provide the circuit size for serving the cooler load, E3702.11. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |