Permit Number: T21CM02255
Parcel: 120086280

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM02255
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/07/2021 PCAMARE1 ENGINEERING REVIEW Passed
04/13/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM02255
207 W Kentucky St
Detached Shed (1st Review)

TRANSMITTAL DATE: April 13, 2021

This site is located in the R-3 zone (Unified Development Code (UDC) Article 4.7.12). A single-family residence is a permitted use in this zone (UDC Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6.

1. Per UDC Article 6.6.3.B Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for terraces and steps not over three feet high above the natural grade, paved areas, and fences or wall. The detached shed located in the front yard will require a Board of Adjustment for Variance. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submittal Type "Zoning Administration".

2. Provide the height of the shed on the plan.

3. The parcel dimensions are not correct and should be 59.25’ x 126.5’.

Based on current aerial photos there is some type of structure located in the southeast corner of the parcel. Show this structure on the plans, provide the size and height and setback dimensions. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-3 Zoning, the required perimeter yard setback to the east property line is 6’ or 2/3 the height of the exterior wall, greater of the two. The required perimeter yard setback to the south property line is 10’ or 3/4 the height of the exterior wall, greater of the two. If this structure does not meet perimeter yard setbacks a reduced perimeter yard setback can be approve either by including the request in the variance process stated above or secure a neighbor signoff for the reduced setback. The neighbor sign off requires the following text to be put on the plot plan and it must be signed by the owner of the adjacent property:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you have any questions about this transmittal, please contact Steve Shields at Steve.Shields@tucsonaz.gov. My email will return an automatic response stating that I have retired but I am currently working as a contract employee and will respond to your questions via email regarding this review.
04/14/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed