Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM02249
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/28/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
07/08/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM02249 1328 E Elm St. Extend Carport and Relocate Electrical Service (3rd Review) TRANSMITTAL DATE: July 8, 2021 This site is located in the R-2 zone (UDC 4.7.9). A single family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10 1. As the dimensions have been changed on the plot plan for the distance from the proposed carport to the east property line a neighbor sign off is required for a setback less than 6’-0” To request the waiver from the adjacent owner the following text must be provided on the plot plan and then signed by the owner at 1340 E Elm: My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 2. This comment was not addressed. As you are expanding the existing garage, adding a carport, the accessory structure may not exceed 50% of the gross floor area of the may dwelling. Per UDC Article 6.6.3.D The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa are exempt from this requirement. It appears that the existing garage already exceeds the 50% of the gfa of the principal structure. A Board of Adjustment for Variance will be required to add the carport extension. Board of Adjustment for Variance application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf, and requires a separate submittal at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type Zoning Administration. The Board of Adjustment will need to be submitted and approved prior to approval of this permit. If you have any questions about this transmittal, please contact Elisa Hamblin at ElisaHamblin@tucsonaz.gov |