Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM02176
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 01/26/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL Nicholas Martell, Planner T21CM02176 New Guest House, SFR (3rd Review) January 26, 2022 The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. Please resubmit the plans addressing the following comments: 1. This comment was not addressed correctly. As there are a total of 6 bedrooms on site 4 vehicle parking spaces are required. These spaces shall meet the requirements below. The plan only shows 2 vehicle parking spaces. Provide a floor plan for the existing home. As the second dwelling unit has more than one (1) bedroom the site is required to meet Unified Development Code Article 4.9.7.B.7 ”for any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms , and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard . A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.” Clearly demonstrate how this requirement is met. Any lot with two residences and 5 or more bedrooms total must have parking spaces developed to a commercial standard. More information is needed regarding the amount of bedrooms in the existing residence to provide a correct parking count. Please include a floor plan of both houses. 2. Zoning acknowledges that a neighbor’s setback waiver was provided but the owners name does not match the owners name provided on the Pima County Assessor’s information. Provide documentation that demonstrates that Mr. Wheeler is the current owner of the property. Also the setback waiver is required to be on the plot plan. Show this structure on the plan and provide setback dimensions. If this structure does not meet required perimeter yard setbacks either a neighbor setback waiver or a Design Development Option (DDO) will be required. The setback waive can be accomplished by providing the text provided below and having the owner of the property to the south sign and date. Please address the structure at the south of the property. It appears to be unpermitted. If that structure is to remain it must be added to the permit, and will likely require a DDO to remain in its current location. If it is no longer present, or to be removed, please indicate. My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |