04/28/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM02176 R1
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. The site plan sheet A-2 shows a stairway to the basement and Section #3 sheet S-1 includes a basement. If included also show a basement plan, R106.1.1.

SECTIONS - DETAILS:

1. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). Update Detail 1-1, sheet F-1.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
(520) 837-4912 PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
05/10/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T21CM02176
New Guest House, SFR (2nd Review)
May 10, 2021

The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.

Please resubmit the plans addressing the following comments:

1. This comment was not addressed. No dimensions were provided on the elevations. Provide dimensions from design grade to the highest point on all walls. Provide full elevation measurements for every side of the new residence. This is used for zoning to determine the required setbacks, and height limitations. In the R-1 zone the height maximum is 25'. Setbacks from a residential use to a residential zone are 6' or 2/3 the height of the building, whichever is greater. It does not appear as though the east, and possibly the south setbacks will be sufficient. The applicant may apply for a Design Development Option (DDO) to reduce those setbacks; but zoning requires completed elevation measurements before that process can be started. The DDO packet can be found here: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf

2. This comment was not addressed. Provide a floor plan for the existing home. As the second dwelling unit has more than one (1) bedroom the site is required to meet Unified Development Code Article 4.9.7.B.7 ”for any new single-family dwelling in the R-1 zone with five bedrooms , three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms , and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard . A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.” Clearly demonstrate how this requirement is met. Any lot with two residences and 5 or more bedrooms total must have parking spaces developed to a commercial standard. More information is needed regarding the amount of bedrooms in the existing residence to provide a correct parking count. Please include a floor plan of both houses.

3. This comment was not addressed. Show this structure on the plan and provide setback dimensions. If this structure does not meet required perimeter yard setbacks either a neighbor setback waiver or a Design Development Option (DDO) will be required. The setback waive can be accomplished by providing the text provided below and having the owner of the property to the south sign and date. Please address the structure at the south of the property. It appears to be unpermitted. If that structure is to remain it must be added to the permit, and will likely require a DDO to remain in its current location. If it is no longer present, or to be removed, please indicate.
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

4. Provide a lot coverage calculation that meets the requirements of Unified Development Code Article 6.4.3. An example of the required lot coverage calculation can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf


If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
05/10/2021 SSHIELD1 NPPO REVIEW Passed