Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM02173
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/05/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
04/05/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM02173 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. STRUCTURAL PLANS: 1. Provide a complete braced wall design, R602.10 or an engineered shear wall design. Include prescriptive braced wall lines, or provide an engineer’s calculation, design and seal. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate water meter size. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. Notate if the mechanical system calculations may be provided by deferred submittal. ELECTRICAL PLANS: 1. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. 2. Clothes Washer and Dishwasher GFCI: receptacles require readily accessible protection typically from an upstream device, E3902.9 & 10. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
04/07/2021 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Engineering Review Section PROJECT: T21CM02173 1715 N MARIPOSA WOODS TRANSMITTAL DATE: April 7, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Engineering Review Section comments were addressed. 01. COMMENT: Engineering has reviewed the plan and cannot approve at this time. Please address the following comments. 02. COMMENT: Engineering cannot approve until Development Package is approved. If you have any questions about this transmittal, Contact Paul Camarena at Paul.Camarena@tucsonaz.gov |
04/13/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | House square footage is 6,462 and shall meet the fire flow required by the IFC. Please provide TFD the type of construction so that we can calculate the required fire flow. You will need to call Tucson Water to see if the fire lines around you can support that number. If the fire flow cannot be met you will need to install fire sprinklers and note that on the drawings. You shall also provide the distance from the closets hydrant to the furthest part of the house. If the number exceeds 400' you shall also install fire sprinklers. If fire flow is met and hydrant distance please provide that letter to TFD. Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
04/21/2021 | EHAMBLI1 | NPPO | REVIEW | Needs Review |