Permit Number: T21CM02143
Parcel: Unknown

Address:
487 S MEYER AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T21CM02143
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/09/2021 STEVE SHIELDS ZONING REVIEW Approved
08/09/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
08/09/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
08/09/2021 SSHIELD1 ENGINEERING REVIEW Passed
08/09/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet G1.1; Project Information: Please list the applicable building codes for this project on this sheet, or add that information on Sheet G1.2.
2. Sheet G1.2; Steel Stair Handrails (Key Notes 5 and 8): Please provide a detail of the 1" x 4" steel weld plate and the epoxy bolt(s) location.
3. Sheet G1.2; Detail Key Notes: Notes 10, 11, and 12 were not located on the handrail elevations. Please verify.
4. Sheet A2.1; Enlarged ADA Bathroom Plan 5: Please indicate on this plan the location of the vertical grab bar from the back wall.
5. Sheet A2.1; General Fixture Clearances: Please list the vertical grab bar with the horizontal grab bars.
6. General: A Petition of Appeal was submitted to the Building Official for the new handrails at the existing stairs and landings at Suites B and C. Please include a copy of the Building Official's decision concerning this appeal in the next submittal.
7. General: Please provide a valuation (labor + materials) for this project.
8. General: Please provide written responses to all review comments.
08/09/2021 ROBERT SHERRY WATER REVIEW Completed
08/09/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
08/09/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
08/20/2021 JPEELDA1 FIRE REVIEW Reqs Change Occupant Load of Common indoor and out door areas shall be provided. Gate being added is a means of egress and shall comply with IFC 2018, 1010.1.2.1 and 1010.1.9.4.

Questions:
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
09/07/2021 JBROWN2 HISTORIC REVIEW Reqs Change Page A2.4 depicts window C and D as 2/4 double hung. The plans reviewed and approved by BHHZAB and PRS show these windows as 2/2 double hung. I have never seen a historic window with fewer panes on the upper sash than the bottom sash. Is there any indication in the rails/stiles that additional muntins were present?
On the same page, window E shows a 6/6 window, but a 2/2 window was what was previously approved. In this instance, the existing window is a 6/6 and it seems appropriate to replace as such.