Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM02143
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/09/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/09/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 08/09/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 08/09/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 08/09/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet G1.1; Project Information: Please list the applicable building codes for this project on this sheet, or add that information on Sheet G1.2. 2. Sheet G1.2; Steel Stair Handrails (Key Notes 5 and 8): Please provide a detail of the 1" x 4" steel weld plate and the epoxy bolt(s) location. 3. Sheet G1.2; Detail Key Notes: Notes 10, 11, and 12 were not located on the handrail elevations. Please verify. 4. Sheet A2.1; Enlarged ADA Bathroom Plan 5: Please indicate on this plan the location of the vertical grab bar from the back wall. 5. Sheet A2.1; General Fixture Clearances: Please list the vertical grab bar with the horizontal grab bars. 6. General: A Petition of Appeal was submitted to the Building Official for the new handrails at the existing stairs and landings at Suites B and C. Please include a copy of the Building Official's decision concerning this appeal in the next submittal. 7. General: Please provide a valuation (labor + materials) for this project. 8. General: Please provide written responses to all review comments. |
| 08/09/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/09/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 08/09/2021 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/20/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Occupant Load of Common indoor and out door areas shall be provided. Gate being added is a means of egress and shall comply with IFC 2018, 1010.1.2.1 and 1010.1.9.4. Questions: Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 09/07/2021 | JBROWN2 | HISTORIC | REVIEW | Reqs Change | Page A2.4 depicts window C and D as 2/4 double hung. The plans reviewed and approved by BHHZAB and PRS show these windows as 2/2 double hung. I have never seen a historic window with fewer panes on the upper sash than the bottom sash. Is there any indication in the rails/stiles that additional muntins were present? On the same page, window E shows a 6/6 window, but a 2/2 window was what was previously approved. In this instance, the existing window is a 6/6 and it seems appropriate to replace as such. |