Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2021 PCAMARE1 ENGINEERING REVIEW Passed
03/23/2021 ANDREW CONNOR NPPO REVIEW Passed
03/25/2021 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T21CM01964
Residential Addition
March 25, 2021

The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.

1. Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. The storage units and other accessory structures are not permitted where they are currently shown on the plans.

a. The applicant may move the structures to the back yard outside of the perimeter yard setback area (6' or 2/3 the height of the structure).
b. The applicant may attach the units to the primary residence with a 5' wide connection that has the capacity to support a 20 pound live load.
c. If the structures are going to be removed, please indicate on the plan.
2. There was an attempted addition on the east part of the residence in 2018 (T18CM07875). That permit was never issued. To get that portion of the residence permitted, it must be added to this permit.
3. If the applicant decides to move the accessory structures there can be a neighbor waiver to reduce the required setbacks. However, the new additions will likely require a Design Development Option (DDO) which can also reduce the required setbacks.


Please reach out to me to discuss how to move forward with this permit or if you have any questions about this transmittal, at Nicholas.Martell@tucsonaz.gov
03/31/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T21CM01964
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

1. Indicate the location of buildings, utility meters and gas, water, electric and sewer lines from property line to building, R106.1.1.

FLOOR PLANS:

1. Show the function of each proposed room, R106.1.1. Function determines code requirements. Include window size and type for egress requirements.
2. Roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside. Provide notation for compliance with R302.1 (City of Tucson Amended) for the altered roof overhang. The fire protected overhang may not extend closer than 24” from the property line. Update detail #2/2.

SECTIONS - DETAILS:

1. Show wood framing members resting on concrete as pressure treated, R317.1 item 2 and show the thickness and type of exterior wood siding. Update detail #2/2
2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update detail #2 & 3/2

ELECTRICAL PLANS:

1. Interior alterations require the installation of smoke alarms at existing bedrooms, R314.2.1. Provide notation if the smoke alarms are existing or proposed.
2. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 (R-30 for a qualifying room addition) and walls R=13. Show the “R” values of insulation and the maximum “U” factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.25, N1102.1.

Please contact the plans reviewer if you have any questions: