Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T21CM01713
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/17/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM01713 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Denied 1-OK 2-Provide duct smoke detector as per IMC-606.2 **Not provided 3-OK 4-OK 5-OK ELECTRICAL REVIEW COMMENTS Conditionally Approved Panel B circuit 18,20 should be corrected to a 2 pole CB and the receptacle should be shown as 208 volt receptacle. Suggest adding GFI receptacle to bathroom at plan east end of building. Suggest to show panels as actual size. Panels shown apear to be 1/2 size. Suggest to show Panel B on lighting sheet as well as power sheet. PLUMBING REVIEW COMMENTS: Denied 1-OK 2-Provide clothes washer with discharge interceptor. IPC-1003.6 **Not provided. Exception-2 only applies to clothes washers for use in individual dwelling units. 3-OK 4-Provide Facility Plumbing Fixture Calculations. IPC-Table-403.1. Provide HI/LO Drinking Fountain.**Not provided. A-8 sheet does not shows Plumbing Fixture Calculations. 5-Provide a drain pan for water heater. Show drain size, material and point of termination. IPC-504.7 **Not provided |
11/19/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM01713 975 E Macarthur Cir. – I-1 New Dentist Office (2nd Review) TRANSMITTAL: November 19, 2021 This site is located in the I-1 zone (UDC 4.7.29), Medical Service Outpatient is an allowed use in the zone (UDC Table 4.8-5), subject to Use Specific Standard 4.9.13.Q. 1. Zoning did a cursory review and it appears that the building plans match DP21-0143 but until at least one review of the DP has been completed Zoning cannot confirm. Until DP21-0143 is approved Zoning cannot approve the building plan. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
11/29/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | The DP needs to be approved before the building plans can be approved. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |