Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM01521
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/03/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 03/10/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM01531 841 E 37th St Porch Addition to Main Dwelling and Detached Ramada TRANSMITTAL DATE: March 10, 2021 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10 Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall. 1. The proposed porch addition to the main dwelling does not meet the minimum perimeter yard setback to the west property line. Based on a wall height less than 9’-0” the required perimeter yard setback is 6’-0”, proposed is 0’-0”, see UDC Table 6.3-2.A. A Board of Adjustment for Variance is required. 2. The proposed detached ramada does not meet the required minimum perimeter yard setback to the west property line. Based on a wall height less than 9’-0” the required perimeter yard setback is 6’-0”, proposed is 1’-0”, see UDC Table 6.3-2.A. This setback can be included in the required Board of Adjustment, see comment 1. 3. The proposed detached ramada does not meet the required minimum side street perimeter yard setback to Tyndall Ave property line. Per UDC Article 6.4.5.C.1.b the minimum side street perimeter yard setback is 10’-0”, proposed is 8’-0” This setback can be included in the required Board of Adjustment, see comment 1. 4. Permits T20CM07588 & T20CM07817 will need to be withdrawn. Provide a written request to withdraw the permits to COTDSDPermits@tucsonaz.gov. Board of Adjustment requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 03/10/2021 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 03/18/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM01521 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. 1. The block wall over 7’ above grade requires a registered engineer’s structural design with professional seal. 2. The ramada requires lateral bracing. 3. The facia connection at detail 5 is not a code compliant structural support for roof live and dead loads. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |